Skip to main content

PCIe2 2-Port 10GbE Base-T, PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter Families for IBM Power Systems

Web Doc

thumbnail 

Published on 20 November 2014, updated 20 January 2015

  1. View in HTML
  2. .PDF (0.5 MB)

Share this page:   

IBM Form #: TIPS1225


Authors: Scott Vetter and Rodrigo Estrada

    menu icon

    Abstract

    This IBM® Redbooks® Product Guide describes the PCIe2 2-Port 10GbE Base-T Adapter and PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter products. These are PCI Express Generation 2 (PCIe2) x8, short form-factor, low-profile capable, regular height network interface card (NIC) adapters. The 2-port adapters enable affordable 10-Gigabit Ethernet (10GbE) network performance with cost-effective RJ45 connections for distances up to 100 meters. The 4-port adapter enables affordable 10-Gigabit Ethernet (10GbE) network performance over SFP+ Multimode Fiber SR optical modules and also supports SFP+ Active Copper cables, depending on the Ethernet switch used. They are compatible with the installed base of GbE switching and cabling infrastructure commonly deployed today.

    Contents

    This IBM® Redbooks® Product Guide describes the PCIe2 2-Port 10GbE Base-T Adapter and PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter products. These are PCI Express Generation 2 (PCIe2) x8, short form-factor, low-profile capable, regular height network interface card (NIC) adapters. The 2-port adapters enable affordable 10-Gigabit Ethernet (10GbE) network performance with cost-effective RJ45 connections for distances up to 100 meters. The 4-port adapter enables affordable 10-Gigabit Ethernet (10GbE) network performance over SFP+ Multimode Fiber SR optical modules and also supports SFP+ Active Copper cables, depending on the Ethernet switch used. They are compatible with the installed base of GbE switching and cabling infrastructure commonly deployed today.

    Figure 1. PCIe2 2-Port 10GbE Base-T Adapter
    Figure 1. PCIe2 2-Port 10GbE Base-T Adapter


    Did you know?

    These network adapters offer an ideal solution for IBM Power System servers that require high-speed data transfer in LAN connectivity for mission-critical applications using existing, affordable cabling and switching IT infrastructure. The adapters provide support for 10Gb networking with CAT 6 copper cable connectivity with the two built-in RJ45 ports. The four-port adapter provides support for 10Gb SFP+ SR fiber or SFP+CU active Copper cable connectivity and 1Gb RJ45 CAT 5/5e cable connectivity.

    Figure 2 shows the PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter.

    Figure 2. PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter
    Figure 2. PCIe2 4-Port (10GbE SFP+ & 1GbE RJ45) Adapter


    Part number information

    Table 1 contains the part numbers and feature codes for ordering these adapters.

    Table 1. Ordering part numbers, CCINs, and feature codes

    DescriptionPart numberCCINFeature code
    PCIe2 2-port 10 GbE BaseT RJ45 Adapter
    00E27182CC4EN0W
    PCIe2 LP 2-port 10 GbE BaseT RJ45 Adapter00E27182CC4EN0X
    PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter00E27192CC3EN0S
    PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter00E27192CC3EN0T
    PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter00E27192CC3EN0U
    PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter00E27192CC3EN0V

    PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapters and PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapters specifications (CCIN: 2CC3 FC: EN0S, EN0T, EN0U, and EN0V):
    • Adapter field-replaceable unit (FRU) number: 00E2715 (complies with RoHS requirement)
    • Low-profile tailstock part number: 00E2720
    • Wrap plug FRU numbers:
      • 12R9314 (SFP+ SR wrap plug)
      • 74Y7010 (Twinax wrap plug)
      • 10N7405 (1 Gb unshielded twisted pair (UTP) wrap plug)
    • I/O bus architecture: PCIe2 x8

    PCIe2 2-port 10 GbE BaseT RJ45 Adapters (CCIN: 2CC4 FC: EN0W EN0X) specifications:
    • Adapter FRU number: 00E2714 (complies with RoHS requirement)
    • Regular-height tailstock part number: 00E2862
    • Low-profile tailstock part number: 00E2721
    • Wrap plug FRU number: 10N7405 (RJ45 wrap plug)
    • I/O bus architecture: PCIe2 x8

    Cables: PCIe2 4-Port (10Gb+1GBE) SR+RJ45 Adapters

    These adapters (CCIN: 2CC3 FC: EN0S and EN0T) use multimode fiber optic cables with shortwave lasers. Table 2 lists cable details.

    Table 2. Supported distances for multimode fiber optic cables
    Cable typeOM1*OM2**OM3
    Specification
    Multimode 62.5/125 micron fiberMultimode 50/125 micron fiberMultimode 50/125 micron fiber
    Bandwidth200 MHz x km 500 MHz x km 2000 MHz x km
    Supported distances0.5 meters to 33 meters (1.64 feet to 108.26 feet)0.5 meters to 82 meters (1.64 feet to 269.02 feet)0.5 meters to 300 meters (1.64 feet to 984.25 feet)
    * Because core sizes differ, OM1 cables can be connected only to other OM1 cables.
    ** For best results, OM2 cables must not be connected to OM3 or OM4 cables. However, if an OM2 cable is connected to an OM3 or OM4 cable, the OM2 cable characteristics apply to the entire length of the cables.

    Cables: PCIe2 4-Port (10Gb+1GBE) Copper SFP+RJ45 Adapters

    These adapters (CCIN: 2CC3 FC: EN0U and EN0V) use 10 Gb copper twinax Ethernet cables listed in Table 3.

    Table 3. Feature code and part number for varying lengths of the cable
    CharacteristicsCable, by length
    Length
    1 m (3.28 ft)3 m (9.84 ft)5 m (16.4 ft)
    Feature codeEN01EN02EN03
    CCINEF01EF02EF03
    Part number46K618246K618346K6184

    Cables: PCIe2 2-Port 10 GbE GBaseT Adapters

    These adapters (CCIN: 2CC4 FC:EN0W and EN0X) use the (4-pair) CAT 6A cables.


    Features and specifications

    The adapters provide the following features:
    • Are PCIe2 NIC network convergence adapters.
    • Can be used as the host local area network (LAN) adapter.
    • Support interrupt moderation to deliver increased performance while significantly reducing processor utilization
    • Support dual port operation in any PCIe3 or PCIe2 slot.
    • Support auto-negotiation, full-duplex only.
    • Support multiple media-access control (MAC) per interface.
    • Support integrated media-access control (MAC) and physical layer (PHY).
    • Provide message signal interrupts (MSI), MSI-X, and support of legacy pin interrupts.
    • Support jumbo frames up to 9.6 KB.
    • Support gigabit Ether Channel (GEC) with the existing software.
    • Support TCP checksum offload transmission control protocol (TCP), user datagram protocol (UDP), TCP segmentation Offload (TSO) for IPv4 and IPv6.
    • Support TCP segmentation or large send offload
    • Support EEPROM-SPI and single EEPROM
    • Comply with the following protocols:
      • IEEE 802.3ae in the 10 GbE ports
      • IEEE 802.3ab in the 1 GbE ports
      • Ether II and IEEE 802.3 for encapsulated frames
      • IEEE 802.1p for setting up priority levels in tagged VLAN frames
      • IEEE 802.1Q for VLAN tagging
      • IEEE 802.3x for flow control
      • IEEE 802.3ad for load-balancing and failover
      • IEEE 802.3ad and 802.3 for link aggregation


    Supported servers

    Table 4 identifies the IBM Power System servers that are supported by these adapters.

    Table 4. Servers supported by the adapters
    IBM Power SystemPart numbers (CCINs) and feature codes
    00E2719 (2CC3)00E2718 (2CC4)
    EN0SEN0TEN0UEN0VEN0WEN0X
    S812L (8247-21L)
    NoYesNoYesNoNo
    S814 (8286-41A)YesNoYesNoYesNo
    S822 (8284-22A)NoYesNoYesNoYes
    S822L (8247-22L)NoYesNoYesNoNo
    S824 (8286-42A)YesNoYesNoYesNo
    S824L (8247-42L)YesNoNoNoYesNo
    E870 (9119-MME)YesYesYesYesYesYes
    E880 (9119-MHE)YesYesYesYesYesYes


    Supported operating systems and device drivers

    The adapters support the following IBM AIX®, Linux, and IBM i operating systems and device drivers:

    AIX (all adapter feature codes support these AIX versions):
    • AIX 7.1, Technology Level 3, Service Pack 2, or later
    • AIX 7.1, Technology Level 2, Service Pack 2, or later
    • AIX 7.1, Technology Level 1, Service Pack 3, or later
    • AIX 6.1, Technology Level 9, Service Pack 2, or later
    • AIX 6.1, Technology Level 8, Service Pack 3, or later
    • AIX 6.1, Technology Level 7, Service Pack 2, or later

    Linux (all adapters feature codes support these versions of Linux):
    • Red Hat Enterprise Linux Version 6.5 or later; current maintenance updates are available from Red Hat.
    • SUSE Linux Enterprise Server 11, Service Pack 3, or later; current maintenance updates are available from SUSE.

    For support and important notices, see the Linux on IBM web page:
    http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/info/LinuxAlerts.html

    IBM i (Table 5 lists IBM I versions that are applicable to the adapter feature codes).

    Table 5. IBM i version applicable to adapter feature codes
    IBM iPart numbers (CCINs) and feature codes
    00E2719 (2CC3)00E2718 (2CC4)
    EN0SEN0TEN0UEN0VEN0WEN0X
    IBM i Version 7.2
    Yes NoYes NoYesNo
    IBM i Version 7.1 or laterYesYesYesYesYesYes
    Supported on Firmware level 8.1No NoYesYesNoNo

    Device drivers

    Table 6 lists the device drivers that are needed for the adapters.

    Table 6. Device drivers
    Device driversPart numbers (CCINs) and feature codes
    00E2719 (2CC3)00E2718 (2CC4)
    EN0SEN0TEN0UEN0VEN0WEN0X
    AIX: devices.pciex.e4148a1614109304 for SFP+ optical ports and
    devices.pciex.e4148a1614109404 for RJ45 ports
    Yes YesYes YesNoNo
    AIX: devices.pciex.e4148e1614109204NoNoNoNoYesYes
    Linux: bnx2x driverYes YesYesYesYesYes
    To download the current version of the device driver or Power RAID adapter utilities (iprutils), go to the IBM Service and productivity tools website:
    http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/home.html


    Popular configuration

    Figure 3 shows a common configuration using these adapters with two IBM Power Systems® that are connected via an Ethernet network.

    Figure 3. Power Systems using Ethernet
    Figure 3. Power Systems using Ethernet


    Warranty

    When these adapters are installed in a supported IBM server, they assume your system's base warranty.


    Physical specification

    Table 7 lists the physical specifications for these adapters.

    Table 7. Physical specifications
    DimensionPart numbers (CCINs)
    00E2719 (2CC3)00E2718 (2CC4)
    Width
    0.7"0.7"
    Length6.6"6.6"
    Height2.731"2.731"
    Height with bracket4.725"4.725"
    Weight450 g (0.99 lb.)450 g (0.99 lb.)


    Operating environment

    The adapters are supported in the following environment:
    • Temperature:
      • Operating: 0° to 55°C (32° to 131 °F) at 0 - 914 m (0 - 3000 ft)
      • Storage: -40° to 65°C (-40° to 149°F) at 0 - 914 m (0 - 3000 ft)
    • Relative humidity: 5% - 95% (non-condensing)


    Agency approvals

    The adapters are compliant with European Union Directive 2002/95/EC on the Restriction of the Use of
    Certain Hazardous Substances in Electrical and Electronic Equipment.

    Table 8 lists FCC Classifications that are available for these adapters. Date format is mm/dd/yy.

    Table 8: FCC Classifications
    ClassificationPart numbers (CCINs)
    00E2719 (2CC3)00E2718 (2CC4)
    ClassDateClassDate
    FCC Rules, Part 15
    B01/13/13A08/09/13
    Industry Canada, ICES-003 B01/13/13A08/09/13
    EN55022 (emissions portion of the CE Mark)B03/11/13A08/19/13
    EN55024 (immunity portion of the CE Mark)N/A03/11/13N/A08/19/13
    CISPR22-
    -
    Australia/New Zealand (C-Tick Mark)B01/13/13A08/19/13
    Japan VCCIB01/25/13A08/19/13
    Taiwan BSMIB01/30/13A10/18/13
    Korea B02/20/13A09/10/13


    Related information

    See these resources for more information about the adapters:

     

    Others who read this also read

    Special Notices

    The material included in this document is in DRAFT form and is provided 'as is' without warranty of any kind. IBM is not responsible for the accuracy or completeness of the material, and may update the document at any time. The final, published document may not include any, or all, of the material included herein. Client assumes all risks associated with Client's use of this document.